PerformanceLongevity

Mitovit Hypoxic Therapy

A professional, computer-controlled altitude-training system that alternates oxygen-reduced and oxygen-enriched air to deliver personalised intermittent hypoxic-hyperoxic training (IHHT) - designed and manufactured in Germany.

Key features
  • Personalised IHHT Controlled intervals of oxygen-reduced and oxygen-enriched air, tailored to each user.
  • Simulates Altitudes up to ~6,750 m Oxygen concentrations from 18% down to 9%, with recovery phases up to 30%.
  • Automated Hypoxia Test Establishes each user's individual starting values on the first session.
  • Intelligent Biofeedback Automatically adapts oxygen delivery to maintain the target SpO₂ range.
  • Dual Pulse Oximetry Continuous SpO₂ monitoring for safe, controlled sessions.
  • Integrated Real-Time HRV Tracks heart-rate variability and parasympathetic activity.
  • Adaptive Hyperoxia Recovery Oxygen-enriched recovery air until the target is reached.
  • Flexible Training Modes Manual, biofeedback and sport modes for wellness, recovery and performance.
  • German-Engineered & UK-Supported Replaceable components, professional installation and operator training.
Ideal for
  • Wellness studios, luxury health clubs and spas
  • Recovery providers and performance centres
  • Longevity specialists and physiotherapy clinics
  • Elite athletes and sports professionals
  • Corporate wellbeing programmes
Specifications
Training technology
Intermittent Hypoxic-Hyperoxic Training (IHHT)
Simulated altitude
Approx. 1,200-6,750 m
Hypoxic oxygen range
18%-9% O₂
Recovery oxygen range
~21% normoxia / up to 30% hyperoxia
SpO₂ target
Adjustable 77%-93%
Training modes
Manual, Biofeedback & Sport
Monitoring
Dual pulse oximeters & real-time HRV
Display
18.5-inch Full HD touchscreen
Dimensions (W × H × D)
Approx. 47.5 × 106 × 42 cm
Weight
Approx. 68.8 kg
Data & connectivity
Unlimited users · PDF/USB export · optional cloud
Payment plan available
Expert UK-wide delivery & installation
Operator training included & UK-based support
Mitovit Hypoxic Therapy session in a relaxed wellness setting
Why choose Mitovit

Personalised altitude training, automated.

The MITOVIT system combines intelligent automation, real-time physiological monitoring and advanced oxygen control to deliver a personalised, professional altitude-training experience.

Automated Hypoxia Test

Establishes individual starting values based on the user's response.

Intelligent Biofeedback

Adjusts oxygen to maintain the selected SpO₂ range.

Adaptive Hyperoxia

Provides oxygen-enriched air until the recovery target is reached.

Dual Pulse Oximetry

Simultaneous SpO₂ monitoring supports safe, controlled sessions.

Integrated HRV Analysis

Tracks HRV and parasympathetic activity in real time.

Flexible Training Modes

Supports guided, self-service and sport applications.

Mitovit Hypoxic Score

Measures session intensity and helps compare progress.

Progress Reporting

Stores session history and displays clear training data.

German Engineering

German-developed system with replaceable components and professional support.

Installation & compliance

Professionally installed and supported.

Professional installation and commissioning are included with every purchase, with a mobile design and lockable wheels for easy positioning.

Installation requirements
  • A solid, level indoor floor with adequate operating space
  • A standard earthed electrical connection
  • A minimum 30 cm clearance from walls, in a well-ventilated room
  • An operating temperature of 18°C-38°C, away from heat and direct sunlight
  • A dry environment, away from bathrooms, chlorine and liquids, using approved accessories only
MITOVIT is developed and manufactured in Germany according to the manufacturer's applicable safety, quality and technical requirements. Product-specific declarations of conformity, certification details and supporting compliance documentation are available upon request.

Mitovit is an altitude-training device and should only be used as intended by trained or experienced operators. Users should be appropriately screened and sessions conducted according to the manufacturer's instructions. Potential side effects of hypoxic training may include headache and dizziness.

FAQ

Frequently asked questions.

IHHT alternates short intervals of oxygen-reduced (hypoxic) air with oxygen-enriched (hyperoxic) recovery air, simulating altitude while you rest. Mitovit automates and personalises each interval to your response.

An automated hypoxia test sets your individual starting values, then intelligent biofeedback adjusts the oxygen concentration in real time to hold your target SpO₂ range, monitored by dual pulse oximeters and HRV analysis.

It is designed for professional wellness, recovery and performance settings and should be operated by trained or experienced operators, with users appropriately screened. We include operator training with every installation.

It is approximately 47.5 x 106 x 42 cm and around 68.8 kg, on a standard earthed supply, with a minimum 30 cm clearance from walls in a well-ventilated room.

Data sheet

Request the data sheet.

Pop in your details and we'll email you the full Mitovit Hypoxic Therapy specification sheet.

Data sheet request
Request a quote

Interested in the Mitovit Hypoxic Therapy?

Enquiry
I'm enquiring as